WISCO International

Kenwood

Home Page | Manufacturers | Kenwood | TK-190 | Quotation | Search | E-mail

Specifications

 

General

TK-190

Frequency Range
   Type 1
   Type 2


29.7 ~ 37.0 MHz
35.0 ~ 50.0 MHz

Number of channels

16

Channel Spacing

20 kHz/ 25 kHz
(PLL step: 5 kHz

Channel Frequency Spread
   Type 1
   Type 2


7.3 MHz
15 MHz

Antenna Impedance

50 Ohm

Operating voltage

7.5 V DC

Battery life KNB-17A (1500 mAh)
5-5-90 duty cycle with battery saver off

8 hours at 6 W

Operating temperature range

-22�F ~+ 140�
(-30� C ~ +60� C)

Frequency stability

� 5 ppm (-22�F ~ +140�F)

Dimensions (W x H x D)
(projections not included)

2-5/16 x 6 1/8 x 1-1/2 in.(58 x 155 x 38 mm)
with KNB-17A battery)

Weight (net)

21.2 oz (600 g) with KNB-17A battery,
without antenna)

RECEIVER (Measurements made per EIA/TIA-204D) TK-190
Sensitivity (12 dB SINAD)

0.25�V

Selectivity

70 dB

Intermodulation 65 dB
Spurious response

70 dB

Audio output

500 mW with less than 3% distortion

TRANSMITTER (Measurements made per EIA-152C)
RF power output (HI/Low)

6W / 1W

Spurious response

55 dB / 60 dB

FM noise

45 dB

Modulation distortion

Less than 3%

Modulation

16K�F3E

Microphone impedance

1.6 kW

Standard MIL 810C
Methods/Procedures
MIL 810D
Methods/Procedures
MIL 810E
Methods/Procedures
Low Pressure 500.1/Procedure I 500.2/Procedure I 500.3/Procedure I
High Temperature 501 .I/Procedure I, II 501.2/Procedure I, II Cat.A1 501.3/Procedure I, II
Cat.A1
Low Temperature 502.I/Procedure I 502.2/Procedure I, II
Cat.C1
502.3/Procedure I, II
Cat.C1
Temperature Shock 503.1/Procedure I 503.2/Procedure I
Cat.A1, C1
503.3/Procedure I
Cat.A1, C1
Solar Radiation 505. I/Procedure I 505.2/Procedure I 505.3/Procedure I
Rain 506.1/Procedure I, II 506.2/Procedure I, II 506.3/Procedure I, II
Humidity 507.I/Procedure II 507.2/Procedure II 507.3/Procedure II
Salt Fog 509.I/Procedure I 509.2/Procedure I 509.3/Procedure I
Dust 510.I/Procedure I 510.2/Procedure I 510.3/Procedure I
Vibration 514.2/Procedure VIII,X 514.3/Procedure I 514.4/Procedure I Cat 8
Shock 516.2/Procedure I, II, X 516.3/Procedure I, IV 516.4/Procedure I, IV
WISCO International, Inc. - MIAMI, FL U.S.A.
Fax: (954) 370-3997 | E-mail: wiscointl@wiscointl.com

Home Page | Manufacturers | Kenwood | TK-190 | Quotation | Search | E-mail