Specifications |
General | |
Frequency Range* |
|
Mode |
F3E |
Number of Channels |
100 ch** |
Power Requirements |
DC 6.0 - 9.0 V (7.5 V nominal) |
Antenna Impedance | 50 |
Operating Temperature | -10� to +50� C |
Battery Life (5-5-90 duty cycle) [with PB-43N] |
|
Frequency Stability |
�5 ppm |
Dimensions [with PB - 43N] |
58 x 120 x 28.4 mm |
Weight |
375 g |
Receiver | |
Circuitry |
Double Super Heterodyne |
Sensitivity (12dB SINAD) | Less than 0.18 �V |
Squelch Sensitivity | Less than 0.13 �V |
Selectivity |
|
Intermediate Frequency |
|
Spurious Response | 55 dB |
Audio Output | More than 400 mW (10 % distortion) |
Transmitter (Measurements made per TIA/EIA-603) |
|
RF Power Output (approx.) |
|
Modulation | Reactance modulation |
Spurious Emission | Less than -60 dB |
Maximum Frequency Deviation | �5 kHz |
Audio Distortion | Less than 3 % |
*Guaranteed Range: 144-148 MHz |
Kenwood reserves the right to change specifications and features without prior notice. |
Applicable MIL-STD |
Standard | MIL 810C Methods/Procedures |
MIL 810D Methods/Procedures |
MIL 810E Methods/Procedures |
MIL 810F Methods/Procedures |
Low Pressure | 500.1 / Procedure 1 | 500.2 / Procedure 1,2 | 500.3 / Procedure 1,2 | 500.4 / Procedure 1,2 |
High Temperature | 501.1 / Procedure 1,2 | 501.2 / Procedure 1,2 | 501.3 / Procedure 1,2 | 501.4 / Procedure 1,2 |
Low Temperature | 502.1 / Procedure 1 | 502.2 / Procedure 1,2 | 502.3 / Procedure 1,2 | 502.4 / Procedure 1,2 |
Temperature Shock | 503.1 / Procedure 1 | 503.2 / Procedure 1 | 503.3 / Procedure 1 | 503.4 / Procedure 1,2 |
Rain | 506.1 / Procedure 2 | 506.2 / Procedure 2 | 506.3 / Procedure 2 | 506.4 / Procedure 3 |
Humidity | 507.1 / Procedure 2 | 507.2 / Procedure 2 | 507.3 / Procedure 2 | 507.4 |
Dust | 510.1 / Procedure 1 | 510.2 / Procedure 1 | 510.3 / Procedure 1 | 510.4 / Procedure 1,3 |
Vibration | 514.2 / Procedure 8,10 | 514.3 / Procedure 1 Cat 8 | 514.4 / Procedure 1 Cat 8 | 514.5 / Procedure 1 Cat 20 |
Shock | 516.2 / Procedure 1,2 | 516.3 / Procedure 1,4 | 516.4 / Procedure 1,4 | 516.5 / Procedure 1,4 |