Output Voltage: |
0-16V DC continuously variable the coarse and fine
controls. |
Load Current: |
0-4 Amp max., continuously variable with coarse and
fine controls. |
Constant Volt.Mode Regulation: |
Less than +/-0.02% +2mV for +/-10% change in line
voltage. |
Load: |
Less than +/-0.02% +2mV for load change from zero
to full load. |
Ripple & Noise: |
Less than 1mV rms max (20Hz - 20MHz) |
Constant Current Reg. Line: |
Less than +/-0.5% +250uA for +/-10% change in line
voltage. |
Load: |
Less than +/-0.5% +250uA for change in output
voltage from O volts to maximum output voltage. |
Ripple & Noise: |
Less than 4mA rms. |
Output Polarity: |
Floating w.r.t. ground. |
Overload Protection: |
Automatic overload and short circuit protection. |
Transient Response: |
100usecs to within 10mV of set output volt.for load
change from 10% to 90% |
Stability - Total drift within 8 hours,
line after warm up under constant load & temp. |
+/-0.1% +2mV in constant voltage mode. |
+/-0.5% +2mV in constant current mode with constant
line, load and ambient temperature conditions. |
Panel Meters: |
Digital panel meter provided with an accuracy of
+/-3 counts. |
Mode Indication: |
Respective LED lights up when the unit is working
in CV or CC mode. |
Output Controls: |
Single turn coarse & fine controls & current
controls provided on front panel. |
Operating Temperatures: |
0-50 degrees C |
Input Voltage: |
115V AC, +/-10% 46-63 single phase. |