MODEL 807 |
MPT 1327 Single Site
Controller INTRODUCTION The MPT 1327 trunked mobile radio standard is internationally recognized for public and private radio systems. Zetron�s Model 807 Trunking Controller implements this standard in an economical, entry level controller package designed for single-site dispatch applications. Its modular design approach ensures a cost-effective system with the facility to add telephone interconnect at the site by connecting to a Model 827 controller fitted with the telephone interface option. BENEFITS CALL TYPES
Features TRUNKING CONTROLLER
TELEPHONE INTERCONNECT USING MODEL 827
|
Specifications |
PHYSICAL | |
Power | 10.5 to 16 Volts DC, 12 Watts |
Temperature | 0 to 60 deg. Celsius |
Size | 48.3 cm W x 4.5 cm H x 26.3 cm D |
Weight | 3 Kg |
RADIO Conforms to MPT 1327/1343 trunking standard. Supports radios compliant with MPT 1327/1352. Full-duplex or half-duplex operation. |
|
RADIO INTERFACE | |
PTT | Form-C relay closure 1 amp @ 30 volts max. |
COR | External COR/CAS, polarity select, Internal Squelch |
Tx Audio | Adjustable -40 to 3 dBm. 1K ohm impedance @ 1000hz |
Rx Audio | Adjustable -40 to 3 dB. Single or differential input 50K ohm impedance @ 1000hz |
Connector | 12 position detachable screw strip |
Modulation | depends on transmitter |
SITE CAPACITY | |
Channels | 24 radio channels at a single site |
Subscribers | 5,000 subscribers expandable to 8,000 |
Groups | 2000 group identities |
Fleets | 500 fleets |
ACCOUNTING | |
Record Types | Registration, status, mobile-to-mobile |
Capacity | Minimum 3656 to a maximum of 7313 records stored internally. Actual record size depends on call type. |
Stored Information | Called/Calling prefix and ID, start date/time, call duration, channel. |
Filtering | Storage of registration and status records can be set to on or off. |
ADDITIONAL | |
Indicators | Repeater, PTT, COR, Alarm, Bus, Status (VOX detect, FFSK Rx, FFSK Tx, poll, sync, not used, not used, not used) |
Data Retention | Retains data for over 8,000 hours when power is removed from unit. There is no drain on the battery when the unit is operating. |
Real-Time Clock | Typically 10 year shelf-life. |
Programming | Remote programming via
PC using M827Base Database Programming Software. Access via internal modem or local RS-232 port |
Alarm Monitoring | 3 specific system alarms plus 3 nonspecific |
Alarm Inputs | 0-5volts Active: ground Inactive: open circuit |
Alarm Outputs | 100mA - 10 Volts Active: grounds control output, Inactive: control output open circuit. |
APPROVALS CE Approved |
WISCO International, Inc. -
MIAMI, FL U.S.A. Fax: (954) 370-3997 | E-mail: wiscointl@wiscointl.com |