MPT 1327 Single Site Controller

 

MPT 1327 Single Site Controller
The MPT 1327 trunked mobile radio standard is internationally recognized for public and private radio systems. Zetron�s Model 807 Trunking Controller implements this standard in an economical, entry-level controller package designed for single-site dispatch applications. Its modular design approach ensures a cost-effective system with the facility to add telephone interconnect at the site by connecting to a Model 827 controller fitted with the telephone interface option.

INTRODUCTIONMODEL 807

The MPT 1327 trunked mobile radio standard is internationally recognized for public and private radio systems. Zetron�s Model 807 Trunking Controller implements this standard in an economical, entry level controller package designed for single-site dispatch applications. Its modular design approach ensures a cost-effective system with the facility to add telephone interconnect at the site by connecting to a Model 827 controller fitted with the telephone interface option.

BENEFITS

CALL TYPES
The MPT 1327 specification has structured call types with room for user definition. Supported call types include:

  • Individual and group speech calls both simple and inter-prefix
  • Non-prescribed data
  • Normal, priority, and emergency calls
  • Status calls
  • Include calls
  • Short data messages
  • Call diversion, self-initiated and third party
  • Call diversion on no answer and busy
  • Call queuing for busy system or busy called party

Features

TRUNKING CONTROLLER

  • Economical entry-level solution for single-site only dispatch applications
  • Fully MPT 1327/1343 compliant
  • Modular �plug and play� structure enables an economical building block approach to site development with expansion capability of up to 24 channels at a single site
  • Individual Subscriber Validation plus Electronic Serial Number (ESN) checking
  • System configuration software is included and provides easy configuration setup and maintenance from a single local or remote connection
  • External sense and internal alarm input monitoring
  • Four levels of user defined call priority in addition to the three MPT 1327 standard levels
  • Support for an extensive range of MPT 1327 call types
  • Emergency calls can be set to demand resources by pre-emptive clearing of existing calls
  • Cyclic control channel operation for balanced repeater transmitter duty-cycle loading

TELEPHONE INTERCONNECT USING MODEL 827

  • Support PSTN interconnect capability at trunking site by adding a Model 827 fitted with Telco Card interface option

Specifications

 
PHYSICAL
Power 10.5 to 16 Volts DC, 12 Watts
Temperature 0 to 60 deg. Celsius
Size 48.3 cm W x 4.5 cm H x 26.3 cm D
Weight 3 Kg
RADIO
Conforms to MPT 1327/1343 trunking standard. Supports radios compliant with MPT 1327/1352. Full-duplex or
half-duplex operation.
RADIO INTERFACE
PTT Form-C relay closure
1 amp @ 30 volts max.
COR External COR/CAS, polarity select, Internal Squelch
Tx Audio Adjustable -40 to 3 dBm. 1K ohm impedance @ 1000hz
Rx Audio Adjustable -40 to 3 dB. Single or differential input 50K ohm impedance @ 1000hz
Connector 12 position detachable screw strip
Modulation depends on transmitter
SITE CAPACITY
Channels 24 radio channels at a single site
Subscribers 5,000 subscribers expandable to 8,000
Groups 2000 group identities
Fleets 500 fleets
ACCOUNTING
Record Types Registration, status, mobile-to-mobile
Capacity Minimum 3656 to a maximum of 7313 records stored internally. Actual record size depends on call type.
Stored Information Called/Calling prefix and ID, start date/time, call duration, channel.
Filtering Storage of registration and status records can be set to on or off.
ADDITIONAL
Indicators Repeater, PTT, COR, Alarm, Bus, Status (VOX detect, FFSK Rx, FFSK Tx, poll, sync, not used, not used, not used)
Data Retention Retains data for over 8,000 hours when power is removed from unit. There is no drain on the battery when the unit is operating.
Real-Time Clock Typically 10 year shelf-life.
Programming Remote programming via PC using M827Base Database Programming Software.
Access via internal modem or local RS-232 port
Alarm Monitoring 3 specific system alarms plus 3 nonspecific
Alarm Inputs 0-5volts
Active: ground
Inactive: open circuit
Alarm Outputs 100mA - 10 Volts
Active: grounds control output,
Inactive: control output open circuit.
APPROVALS
CE Approved
WISCO International, Inc. - MIAMI, FL U.S.A.